Shelter Model |
(4) CAMSS 18TAC25, (3) CAMSS 14TAC15, (3) TAC Corridors, (2) 18TAC Cover to Cover Connectors, (1) TAC Double Corridor
|
Part Number |
(4) CAMSS18TAC25, (3) CAMSS14TAC15, (3) CAMSS-TAC7-COR, (2) CAMSS18TAC-CTC-01, (1) CAMSS-TAC14-COR
|
Square Footage |
2430 Sq. Ft. of Shelter Space
|
Set-Up and Strike Time / People |
4 Minutes / 4 People Per 18TAC25, 3 Minutes / 4 People Per 14TAC15
|
Typical Uses |
Battalion Operations, Rapid Deployment, TOC, Command Post
|
Frame Arches |
Anodized Aluminum Folding Frame
|
Cover & End Panels |
15 oz/sq yd Mil-Spec 44103D with FR, IR, Blackout, UV and Mildew Resistance
|
Windows |
Mesh Windows with Blackout Covers
|
Zipper Entry |
Double Zipper Entries (36″ x 84″) with Boot Connectors
|
Floor |
Non-Slip Mil-Spec 44103D with Vector Proofing and is Removable without Shelter Disassembly
|
Liner |
8 oz/sq yd White Mil-Spec Liner Fabric with FR, Blackout, UV and Mildew Resistance
|
ECU Ports and Air Sock |
Sets include Two (2) 18″ ECU Ports, a Cable Port, and a Fabric Air Sock with Spot Cooling
|
Electrical |
Quick Connect 110V Outlets
|
Anchoring |
Double Headed 18″ Anchoring Spikes and Guy Ropes with Guy Spikes
|
Extreme Temperatures |
Designed to Maintain Inside Temperatures of 40° to 80°F in Ambient Temperatures of -25° to 125° F with ECUs
|
Wind |
Meets TOP 10-2-175 Wind Load Test Per Test Report of Similar Type Shelter (NATC testing of CAMSS20TAC20)
|
Snow |
Meets TOP 10-2-175 Snow Load Test Per Test Report of Similar Type Shelter (NATC testing of CAMSS20TAC20)
|
Durability |
40+ Set-up/Strikes and Be Fully Deployable (U.S. Army Aberdeen Test Center and CAMSS testing of CAMSS20TAC20)
|
Wind Driven Rain |
Wind-Driven Rain Test in Accordance with TOP 10-2-175 Section 4.9.2.2. Per Test Report of Similar Type Shelter (NATC testing of CAMSS20TAC20)
|
Blackout |
Military TOP 10-2-175 Blackout Test at 100m with Naked Eye and 300m with Night Vision Goggles Per Test Report of Similar Type Shelter (U.S. Army Aberdeen Test Center testing of CAMSS20TAC20)
|